International Journal For Multidisciplinary Research
E-ISSN: 2582-2160
•
Impact Factor: 9.24
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Home
Research Paper
Submit Research Paper
Publication Guidelines
Publication Charges
Upload Documents
Track Status / Pay Fees / Download Publication Certi.
Editors & Reviewers
View All
Join as a Reviewer
Reviewer Referral Program
Get Membership Certificate
Current Issue
Publication Archive
Conference
Publishing Conf. with IJFMR
Upcoming Conference(s) ↓
WSMCDD-2025
GSMCDD-2025
Conferences Published ↓
RBS:RH-COVID-19 (2023)
ICMRS'23
PIPRDA-2023
Contact Us
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 6 Issue 6
November-December 2024
Indexing Partners
Design And Development Of Automated Electrical Circuit Fault Protector With Alarm System
Author(s) | Prof. George D. Daliva |
---|---|
Country | Philippines |
Abstract | In response to the critical need for fire and accident prevention in homes and establishments, this research presents an automated electrical circuit fault protector with an alarm system. The device automatically interrupts current flow upon detecting short circuits and overloads, safeguarding against potential hazards. Objectives include assessing sensitivity to faults, evaluating wireless remote-control performance, examining sound clarity, and ensuring voltage stability post-fault events. Equipped with a resettable system, the device allows manual or remote control. Using a developmental research method, data collection employed researcher-made observation and evaluation sheets. Thirty expert evaluators assessed the device. Micro testing revealed that the device was sensitive to faults and automatically triggered the alarm. With an overload rating of 1,500-3,000 watts, the device shuts off power automatically after the overload occurs and back to normal with a stable voltage once the problem was fixed, though this device was primarily designed only for micro-testing this device was customizable to user needs. Its alarm system boasts an audible range of up to 20 meters the same is through with remote control operation. Overall, the device effectively detects faults, incorporates an audible alarm, and supports remote operation, serving as a crucial safety measure against electrical mishaps and very acceptable in terms of design, composition, safety, and operating performance. |
Keywords | Automated electrical circuit fault protector, alarm system, electrical safety, fault detection, short circuit, overload, wireless remote control, alarm signal clarity, voltage stability, design, and development. |
Field | Engineering |
Published In | Volume 6, Issue 3, May-June 2024 |
Published On | 2024-05-17 |
Cite This | Design And Development Of Automated Electrical Circuit Fault Protector With Alarm System - Prof. George D. Daliva - IJFMR Volume 6, Issue 3, May-June 2024. DOI 10.36948/ijfmr.2024.v06i03.20237 |
DOI | https://doi.org/10.36948/ijfmr.2024.v06i03.20237 |
Short DOI | https://doi.org/gtvt22 |
Share this
E-ISSN 2582-2160
doi
CrossRef DOI is assigned to each research paper published in our journal.
IJFMR DOI prefix is
10.36948/ijfmr
Downloads
All research papers published on this website are licensed under Creative Commons Attribution-ShareAlike 4.0 International License, and all rights belong to their respective authors/researchers.