
International Journal For Multidisciplinary Research
E-ISSN: 2582-2160
•
Impact Factor: 9.24
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Home
Research Paper
Submit Research Paper
Publication Guidelines
Publication Charges
Upload Documents
Track Status / Pay Fees / Download Publication Certi.
Editors & Reviewers
View All
Join as a Reviewer
Get Membership Certificate
Current Issue
Publication Archive
Conference
Publishing Conf. with IJFMR
Upcoming Conference(s) ↓
WSMCDD-2025
GSMCDD-2025
Conferences Published ↓
RBS:RH-COVID-19 (2023)
ICMRS'23
PIPRDA-2023
Contact Us
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 7 Issue 2
March-April 2025
Indexing Partners



















Analytical Method Development of Bioactive Compounds in Bacopa monnieri Leaf Extract by RP-HPLC
Author(s) | Ms. Vidhya Arthy J, Akila K S, Harish V, Kowsigan P, Selvakumar S, Veeraragavan P |
---|---|
Country | India |
Abstract | A novel very rapid, sensitive, reverse phase High performance liquid chromatography (RP-HPLC) technique was developed for the quantitative estimation of bioactive compounds in the medicinal plant Bacopa monnieri. Five bioactive compounds namely Bacopasaponin A, Bacoposide I, Bacopaside II, Bacoside A3, Jujobogenin of Bacopasaponin C was resolved by using a mobile phase of phosphate buffer, acetonitrile in the ratio of 60 : 40 % v/v at a flow rate of 1.5ml/min using UV-visible detector at the wavelength of 205nm for quantification. Efficient separation was achieved for Bacopa monnieri on Hypersil BDS C18 (4.6mm X250 mm, 5.0 micron) Column at 30C.With an isocratic elution the separation was obtained in a total run time of 30 mins. The retention time of active constituents was found to be 16.4,9.3,14,13.5,15.4 minutes respectively. Based on the studies it was concluded that the method development of bio active components from Bacopa monnieri were found to be simple, sensitive and inexpensive method. Hence, the development method can be recommended for routine quality control analysis. |
Keywords | Bacopa monnieri, RP – HPLC, UV Detector, Isocratic elution. |
Field | Medical / Pharmacy |
Published In | Volume 7, Issue 2, March-April 2025 |
Published On | 2025-03-27 |
DOI | https://doi.org/10.36948/ijfmr.2025.v07i02.38961 |
Short DOI | https://doi.org/g8936x |
Share this

E-ISSN 2582-2160

CrossRef DOI is assigned to each research paper published in our journal.
IJFMR DOI prefix is
10.36948/ijfmr
Downloads
All research papers published on this website are licensed under Creative Commons Attribution-ShareAlike 4.0 International License, and all rights belong to their respective authors/researchers.
