International Journal For Multidisciplinary Research
E-ISSN: 2582-2160
•
Impact Factor: 9.24
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Home
Research Paper
Submit Research Paper
Publication Guidelines
Publication Charges
Upload Documents
Track Status / Pay Fees / Download Publication Certi.
Editors & Reviewers
View All
Join as a Reviewer
Reviewer Referral Program
Get Membership Certificate
Current Issue
Publication Archive
Conference
Publishing Conf. with IJFMR
Upcoming Conference(s) ↓
WSMCDD-2025
GSMCDD-2025
Conferences Published ↓
RBS:RH-COVID-19 (2023)
ICMRS'23
PIPRDA-2023
Contact Us
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 6 Issue 6
November-December 2024
Indexing Partners
Retrospective Analysis of Treatment Time Calculation Agreement Between TPS and Manual Method and Source Strength Verification for 13 HDR Ir-192 Sources In Flexitron Brachytherapy Unit: A Single Institute Experience
Author(s) | Gurbir Kaur, Aarti Guray |
---|---|
Country | India |
Abstract | Introduction: Source strength measurement and verification during every source exchange in high dose rate (HDR) Brachytherapy 192Ir is primary part of quality assurance program as recommended by national regulatory body Atomic Energy Regulatory Board, Mumbai, India. The purpose of this study was to evaluate RAKR (in-house measurement) of 192Ir using re-entrant well-type ionization chamber with stated RAKR values as provided by the manufacturer in source certificate and to check the accuracy of the Oncentra treatment planning system calculation with manual method of computation at different intervals for 13 HDR Ir-192 sources. Materials And Methods: We have retrospectively evaluate the in-house measured RAKR with the calibrated Standard Imaging HDR 1000 PLUS Well chamber /electrometer CDX 2000B for 13 HDR Ir192 sources with stated RAKR and the treatment time calculation accuracy of Oncentra TPS verified by manual method of computation using TG-43 formalism. Results: The study shows, that the measured RAKR and stated RAKR were well within the tolerance limits set by the national and international recommendations i.e. ±3 % for 13 HDR Ir192 sources. The verification of TPS treatment time calculation with manual calculation for single source as well as for multi-source lies within ±2%. Conclusions: There is good agreement between in-house measured and vendor quoted values of RAKR which shows that the chamber has been stable to better than ±3 % and manual calculations shows agreement with the TPS outcome within ±2% for 13 HDR Ir192 sources. The manual method of computation works reliably and reassures the TPS functioning. |
Keywords | Brachytherapy,Documentation,Iridium-192 |
Published In | Volume 5, Issue 4, July-August 2023 |
Published On | 2023-07-23 |
Cite This | Retrospective Analysis of Treatment Time Calculation Agreement Between TPS and Manual Method and Source Strength Verification for 13 HDR Ir-192 Sources In Flexitron Brachytherapy Unit: A Single Institute Experience - Gurbir Kaur, Aarti Guray - IJFMR Volume 5, Issue 4, July-August 2023. DOI 10.36948/ijfmr.2023.v05i04.4565 |
DOI | https://doi.org/10.36948/ijfmr.2023.v05i04.4565 |
Short DOI | https://doi.org/gsh528 |