
International Journal For Multidisciplinary Research
E-ISSN: 2582-2160
•
Impact Factor: 9.24
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Home
Research Paper
Submit Research Paper
Publication Guidelines
Publication Charges
Upload Documents
Track Status / Pay Fees / Download Publication Certi.
Editors & Reviewers
View All
Join as a Reviewer
Get Membership Certificate
Current Issue
Publication Archive
Conference
Publishing Conf. with IJFMR
Upcoming Conference(s) ↓
WSMCDD-2025
GSMCDD-2025
Conferences Published ↓
RBS:RH-COVID-19 (2023)
ICMRS'23
PIPRDA-2023
Contact Us
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 7 Issue 2
March-April 2025
Indexing Partners



















Acceptance Testing and Evaluation of the RGSC – Respiratory Gating for Scanners
Author(s) | Priya Jacob |
---|---|
Country | United States |
Abstract | The Respiratory Gating for Scanners (RGSC) system, developed by Varian Medical Systems, is an advanced accessory designed to enhance the precision of diagnostic imaging and radiation therapy by synchronizing image acquisition with the patient’s respiratory cycle. By continuously monitoring and recording respiratory motion, RGSC provides essential data for tumor tracking, motion management, and treatment planning. The system is compatible with CT and PET-CT scanners from leading manufacturers, including Canon, GE, Philips, and Siemens, ensuring seamless integration into various clinical workflows. With an intuitive user interface and enhanced gating accuracy, RGSC plays a crucial role in improving tumor targeting, image quality, and overall treatment outcomes. This study presents our experience with acceptance testing and quality assurance (QA) of the RGSC system integrated with a GE Discovery RT Wide Bore (80 cm) CT simulator, outlining key performance evaluations and validation protocols. The findings serve as a reference for optimizing RGSC implementation in clinical practice while ensuring compliance with established motion management guidelines. |
Keywords | Tumor Motion Tracking, 4D CT Imaging, Radiation Therapy, Quality Assurance, RGSC System, Motion Management, Computed Tomography, Respiratory Motion Management In Radiotherapy, Respiratory Gating.VCD(Visual Coaching Device). |
Field | Engineering |
Published In | Volume 5, Issue 2, March-April 2023 |
Published On | 2023-03-08 |
DOI | https://doi.org/10.36948/ijfmr.2023.v05i02.37548 |
Short DOI | https://doi.org/ |
Share this

E-ISSN 2582-2160

CrossRef DOI is assigned to each research paper published in our journal.
IJFMR DOI prefix is
10.36948/ijfmr
Downloads
All research papers published on this website are licensed under Creative Commons Attribution-ShareAlike 4.0 International License, and all rights belong to their respective authors/researchers.
